Kernel driver pli1209bc¶
Supported chips:
Digital Supervisor PLI1209BC
Prefix: ‘pli1209bc’
Addresses scanned: 0x50 - 0x5F
Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf
- Authors:
Marcello Sylvester Bauer <sylv@sylv.io>
Description¶
The Vicor PLI1209BC is an isolated digital power system supervisor that provides a communication interface between a host processor and one Bus Converter Module (BCM). The PLI communicates with a system controller via a PMBus compatible interface over an isolated UART interface. Through the PLI, the host processor can configure, set protection limits, and monitor the BCM.
Sysfs entries¶
in1_label |
“vin2” |
in1_input |
Input voltage. |
in1_rated_min |
Minimum rated input voltage. |
in1_rated_max |
Maximum rated input voltage. |
in1_max |
Maximum input voltage. |
in1_max_alarm |
Input voltage high alarm. |
in1_crit |
Critical input voltage. |
in1_crit_alarm |
Input voltage critical alarm. |
in2_label |
“vout2” |
in2_input |
Output voltage. |
in2_rated_min |
Minimum rated output voltage. |
in2_rated_max |
Maximum rated output voltage. |
in2_alarm |
Output voltage alarm |
curr1_label |
“iin2” |
curr1_input |
Input current. |
curr1_max |
Maximum input current. |
curr1_max_alarm |
Maximum input current high alarm. |
curr1_crit |
Critical input current. |
curr1_crit_alarm |
Input current critical alarm. |
curr2_label |
“iout2” |
curr2_input |
Output current. |
curr2_crit |
Critical output current. |
curr2_crit_alarm |
Output current critical alarm. |
curr2_max |
Maximum output current. |
curr2_max_alarm |
Output current high alarm. |
power1_label |
“pin2” |
power1_input |
Input power. |
power1_alarm |
Input power alarm. |
power2_label |
“pout2” |
power2_input |
Output power. |
power2_rated_max |
Maximum rated output power. |
temp1_input |
Die temperature. |
temp1_alarm |
Die temperature alarm. |
temp1_max |
Maximum die temperature. |
temp1_max_alarm |
Die temperature high alarm. |
temp1_crit |
Critical die temperature. |
temp1_crit_alarm |
Die temperature critical alarm. |